Vollrath SU412 Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Küche Vollrath SU412 herunter. Vollrath SU412 User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - OWNERS MANUAL

Model U412 SeriesOWNERS MANUALManual No. 513625 Rev.2

Seite 2

4Figure 2-2 Mix Hose Installation2.5 MIX PUMPA. MIX PUMP HOSE INSTALLATIONFollow the steps below to install the mix pump hose in the cabinet part of t

Seite 3 - For U412 Series

5Figure 2-3 Mix Pump Connections for Standard Mix Container2. Connect the free end of the tubing to the mix check valve. Observe the direction of the

Seite 4 - A Few Words About Safety

64. Repeat steps 1 to 3 for the middle port and for the right port of the mix inlet manifold.5. Place three mix bags into the mix container.6. Conn

Seite 5 - CONTENTS

7SECTION 3INITIAL SET-UP AND OPERATION3.1 OPERATOR’S SAFETY PRECAUTIONS SAFE OPERATION IS NO ACCIDENT; observe these rules:A. Know the machine. Read

Seite 6 - 6 Replacement Parts

8C. SPIGOT SWITCHThe spigot switch is mounted to the spigot cam assembly behind the header panel. When the spigot is opened to dispense product, the s

Seite 7 - SECTION 1

93.3 DISASSEMBLY OF MACHINE PARTSWARNINGMoving machinery can grab, mangle and dismem-ber. Place the Main Freezer Power Off/On switch in the OFF positi

Seite 8 - Model SU412

103.8 ASSEMBLING MACHINETo assemble the machine parts, refer to the following steps:NOTICEPetrol-Gel sanitary lubricant or equivalent must be used whe

Seite 9 - INSTALLATION INSTRUCTIONS

113.9 SANITIZINGSanitizing must be done after the machine is clean and just before the machine is fi lled with mix. Sanitizing the night before is not

Seite 10 - 2.5 MIX PUMP

12B. Place the mix pump switch in the ON position and open the air bleed valve on the front door by pushing the valve in and holding (see Figure 3-8)

Seite 11

1313. After entering 8.0, press SET to save this value. The LCD will read “CutOut Set -- OK”.14. Press the SEL button. The LCD will read “CutOut amp

Seite 13 - INITIAL SET-UP AND OPERATION

14E. Place the mix pump switch in the ON position.F. Place a container under the spigot and open the spigot to allow the mix to fl ush out about 8 ou

Seite 14 - ) After pressing the SET

15A. Mix Operation: The peristaltic mix pump contains one continuous mix pump hose. When looking at the face of the peristaltic mix pump, the left si

Seite 15

16A. Loosen the clamp and remove the air hose from the pump compressor.B. Loosen the clamp and disconnect the mix pump hose. Remove the pickup hose,

Seite 16 - 3.7 CLEANING THE MACHINE

194.1 FREEZER ADJUSTMENTThis section is intended to provide maintenance personnel with a general understanding of the freezer adjustments. It is recom

Seite 17 - 3.9 SANITIZING

20IMPORTANT:Before making changes to any settings, record the original values. If the setting changes do not achieve desired results, return settings

Seite 18

21RUN STATISTICS In addition to dynamic readings and recorded error code details, the IntelliTec control records rolling averages of run statistics.

Seite 19 - OPERATION

22Off Time (sec) Increasing this value will increase the time between freezing cycles in “Standby Mode” and result in an increase of product temperat

Seite 20 - 3.13 OPERATION OF MIX PUMP

23A. Turn the mix pump switch to the OFF position. Disconnect power sources/circuit breakers.B. Remove the back panel from the freezer.C. On the ai

Seite 21 - REMOVABLE PARTS

24G. Connect the new mix pump hose to the pickup hose adapter using the small clamp.H. Feed one end of the mix pump hose into the pickup hose side (

Seite 22

25C. If an adjustment is necessary, loosen the four motor plate retaining nuts, adjust belt tension then retighten the four nuts.D. Using a straight

Seite 23 - MAINTENANCE AND ADJUSTMENTS

This manual provides basic information about the machine. Instructions and suggestions are given covering its operation and care.The illustrations and

Seite 25 - PERSONNEL ONLY)

27SECTION 5TROUBLESHOOTING5.1 ERROR CODESWhen the machine experiences a problem, one of the following error codes will be displayed on the control pan

Seite 26 - 4.8 OVERRUN ADJUSTMENT

28Error Code 5 - Freezing Cylinder Sensor The Freezing Cylinder Sensor Error (E5) indicates a failure of the barrel sensor or if the sensor is out of

Seite 27 - 4.9 MIX PUMP HOSE REPOSITION

295.3 TROUBLESHOOTING - MACHINEPROBLEM POSSIBLE CAUSE REMEDYDrive motor (auger) “kicks-out”, or does not run.1. Power to machine is off. 1. Check powe

Seite 28

305.4 TROUBLESHOOTING - MIX PUMPPROBLEM POSSIBLE CAUSE REMEDYPump motor does not run.1. Power to pump is off. 1. Supply power to pump.2. Low voltage.

Seite 29 - 4.15 EXTENDED STORAGE

31PROBLEM POSSIBLE CAUSE REMEDYOverrun too high.1. Mix pump hose service life is exceeded.1. Reposition/replace mix pump hose.2. Out of mix. 2. Replen

Seite 31 - TROUBLESHOOTING

33SECTION 6REPLACEMENT PARTS6.1 BRUSHES, DECALS AND LUBRICATION Part Number Description Quantity 208135 Brush - 4” X 8” X 16” (Barrel) 1 20838

Seite 32

346.2 AUGER SHAFT AND FRONT DOOR PARTS Part Number Description Quantity 162155 Scraper Blade (6.875” Long) 2 482004 Knob (Air Bleed Valve) 1

Seite 33 - 5.3 TROUBLESHOOTING - MACHINE

356.3 BLENDER PARTS AND DRIP TRAY Part Number Description Quantity 274031 Blender Agitator Collar (SU412) 1 417010 Grid - Drip Tray (Metal) 1

Seite 34

Safety Alert Symbol:This symbol Indicates danger, warning or caution. At-tention is required in order to avoid serious personal injury. The message th

Seite 35

366.4 CAB TUBING ASSEMBLY Part Number Description Quantity 264235 Clamp - Metal (1/4” ID Tubing) (Cab) 4 264241 Clamp - Metal (1/2” ID Tubing)

Seite 36

January 30, 2003 721-013, Rev. 0 File: Policy Manual/Warranty softserve1 WARRANTYSOFT SERVE / SHAKE FREEZERS1. Scope: Stoelting, LLC wa

Seite 37 - REPLACEMENT PARTS

TABLE OFCONTENTSSection Description Page 1 Description and Specifi cations 1.1 Description ...

Seite 38

Section Description Page 4 Maintenance and Adjustments 4.1 Freezer Adjustment ...

Seite 39

11.1 DESCRIPTIONThe U412 is an ultra high capacity fl oor model shake machine. It is equipped with fully automatic controls to provide a uniform produ

Seite 40 - 6.4 CAB TUBING ASSEMBLY

21.2 SPECIFICATIONSModel SU412Dimensions Machine with cratewidth 19-1/8’’ (48,6 cm) 27’’ (68,6 cm)height 67’’ (170,2 cm) 78’’ (198,1 cm)depth 38-3/4’’

Seite 41 - SOFT SERVE / SHAKE FREEZERS

3SECTION 2INSTALLATION INSTRUCTIONS2.1 SAFETY PRECAUTIONSDo not attempt to operate the machine until the safety precautions and operating instructions